top of page
clopisrepsaukodi

Trane ADH2 User's Information Manual: A Step-by-Step Guide to Your Condensing Gas Furnace



We include immediate downloads of example installation & repair manuals and wiring diagrams for air conditioners, heat pumps, and heating equipment from a variety of manufacturers as well as contact information to obtain the exact manual or wiring diagram for your unit.


81 Convertible Gas Furnaces S9V2 S9X2 Table FUR-3-A Features Variable Speed Multi-Speed Comfort-R enhanced mode (cooling)... Standard 34" height... 3 Way poise Upflow furnace model (Upflow, Horzontal Left, Horizontal Right)... Dedicated Downflow furnace model... Front service access with easily accessible burners, sensors, orifices, switches, and other components... Cabinet has no knockouts - Rubber and plastic plugs come installed from factory... Gas can enter either side of cabinet... Condensate can exit either side of cabinet in Upflow orientation... Multiple venting options - Every model, every size will offer two venting options... New IntegratedFurnace Control board with digital configuration, status, and fault codes... Improved alpha-numeric diagnostic codes... Dry contact Humidifier/EAC hook-up capability... Adjustable blower off delay for heating and cooling... Last six fault codes are stored (even with power loss)... Stainless steel primary and secondary heat exchanger tubes... Longer IFC wire harnesses allow door to be removed without disconnecting the harness... Alternate bottom/left/right return air (upflow models only)... Bottom panel... Direct drive, variable speed ECM blower motor - Constant airflow ECM (electronically commutated motor)... Direct drive, multi speed ECM blower motor - Constant torque ECM (electronically commutated motor)... Dual PVC pipe venting (1 or 2 pipe option)... Two stage combination gas valve and regulator... Gasketed inner and outer door... Heavy gauge reinforced wrap-around steel cabinet... Insulated blower compartment... Left/right condensate drain capability in vertical application... Service diagnostics with faults reported on IFC board... Manual reset flame roll out switches... Mobile home approved with mobile home kit... Multi-port in shot burners... Painted cabinet two tone color... Service diagnostic capabilities... Vortica II blower housing... Slide out blower assembly on full-length rails... Side return duct starter tabs (upflow models only)... Silicon Nitride 120V hot surface igniter... Multiple heating blower speeds... Meets requirements for 2% or less air leakage... Registered limited lifetime heat exchanger warranty & 10-year on all other functional parts (Residential Use)1... Optional extended warranties available... 1 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at trane.com or by phone at ; otherwise Trane Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on Comfortsite.com. Note: Variable speed furnaces should not be twinned and are not approved for twinning applications.. S9V2-2 Stage S9X2-2 Stage Table FUR-3-B Optional Accessories 1 or 2 Pipe 1 or 2 Pipe Model Number Description Shipping Weight BAYLPSS400A LP Kit with Stainless Steel Burners BAYHANG Horizontal hanging kit BAYVENT200B Sidewall vent Termination Kit fo Direct vent furnaces BAYVENTCN200B Sidewall vent Termination Kit fo Direct vent furnaces for Canadian applications BAYAIR30AVENTA Concentric vent kit for 2, 2 and 3" vent system BAYAIR30CNVENT Concentric vent kit for 2, 2 and 3" vent system for Canadian applications BAYREDUCE Reducer Coupling for Canadian applications (CPVC) BAYLIFTB Dual return kit. B size extension BAYLIFTC Dual return kit. C size extension BAYLIFTD Dual return kit. D size extension BAYMFGH200A Manufactured/mobil home kit BAYBASE205 Downflow subbase BAYFLTR206 Filter Access Door Kit (Downflow only) Furnaces FUR-3




Trane ADH2 User's Information Manual Trane




274 Packaged Gas/Electric Convertible 3-10 Tons Accessories Light Commercial Packaged Gas/Electric Table LPG-10-A Accessories Model Number Description Used Withq BAYABRD001C3... ReliaTel Options Module...All Y*C * BAYASCT001C78... Anti-Short-Cycle Timer...All Y*C * w/ Electro Mechanical BAYBARM010A5... Barometric Relief...YSC036E, YHC036E, YHC037E BAYBARM011A5... Barometric Relief...YSC048E-120E, YHC , YHC BAYBCIR001A... BACnet Communication Interface...All Y*C * w/ ReliaTel BAYCCHT010B... Crankcase Heater...YSC , YSC BAYCCHT011B... Crankcase Heater...YSC , YSC BAYCCHT017A... Crankcase Heater...YSC , YSC090, YSC120 BAYCCHT018A... Crankcase Heater...YSC , YSC090, YSC120 BAYCURB042A2... Roof Curb...YSC E, YSC F, YHC036E, YHC037E BAYCURB043A2... Roof Curb...YSC E, YSC F, YHC072F, YHC047E, YHC067E BAYCURB044A... Roof Curb...YHC120F BAYDFPS003B36... Clogged Filter Switch...All Y*C * BAYDFPS014A... Clogged Filter Switch (MERV 13 Filter)...All Y*C * BAYDFPS Fan Failure Switch...All Y*C * BAYDMPR053B % Manual Outside Air Damper...YSC , YHC036, YHC037 BAYDMPR056B % Manual Outside Air Damper...YSC , YHC , YHC BAYDMPR051A % Motorized Outside Air Damper...YSC , YHC036, YHC037 (ReliaTel ) BAYDMPR052B % Motorized Outside Air Damper...YSC , YHC036 (Electro Mechanical) BAYDMPR054A % Motorized Outside Air Damper...YSC , YHC , YHC (ReliaTel ) BAYDMPR055B % Motorized Outside Air Damper...YHC , YSC , YHC (Electro Mechanical) BAYECON085A % Dry Bulb Economizer...YSC , YHC036, YHC037 (ReliaTel ) BAYECON086B % Dry Bulb Economizer...YSC , YHC036 (Electro Mechanical) without Barometric Relief BAYECON087A % Dry Bulb Economizer...YSC , YHC , YHC (ReliaTel ) BAYECON088B % Dry Bulb Economizer...YHC , YSC , YHC (Electro Mechanical) BAYECON704A... Downflow Low Leak Economizer...YHC047E-067E*R, YHC E*R, YHC F*R, YHC120E*R, YSC( )F*R, YHC F*R, YHC048E-120E*E, YSC( )F*E, YHC( )F*E, YHC092F*E (ReliaTel ) BAYECON705A... Downflow Low Leak Economizer...YSC E*R, YHC036E*R, YHC037E*R, YHC036E*E, YSC E*E (ReliaTel ) BAYENTH300A... Reference Enthalpy Kit (Solid State)...BAYECON086A, 088A (Electro-Mechanical) BAYENTH301A... Comparative Enthalpy Kit (Solid State)...BAYECON086A, 088A (Electro-Mechanical) BAYENTH005A1... Reference Enthalpy Kit...BAYECON085A, 087A (ReliaTel ) BAYENTH006B1... Comparative Enthalpy Kit...BAYECON086A, 087A (ReliaTel ) BAYFRST003A34... High Temperature Stat...All Y*C * BAYGARD037C... Condenser Coil Hail Guard...YSC036-60E, YHC037 BAYGARD040C... Condenser Coil Hail Guard...YSC072E-090E, YHC , YHC BAYGARD041C... Condenser Coil Hail Guard...YSC , YHC072 BAYGARD070A... Condenser Coil Hail Guard...YHC120E BAYGARD141A... Condenser Coil Hail Guard...YSC102F-120F, YHC072F-102F Read q A=R-22, E=410A only BAYHAKT010E... High Altitude Kit...All Y*C * 1 Kits contain all necessary parts to achieve desired level of enthalpy control. 2 Lynn Haven Manufacturing has a No-Return policy for this roof curb. 3 For use with ReliaTel controlled units only. 4 Cannot be used in conjunction with factory installed Smoke Detector option. 5 Installs in ductwork for horizontal configuration. For downflow configuration, it installs in the unit's horizontal return duct. See Installer's Guide for more information. 6 BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A),Discharge Air Sensing Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options include the ReliaTel Options Module. 7 Electromechanical controlled units only 8 Activated on Power on. 9 Field installed accessory. Requires an economizer. 0 The manual outside air damper will ship factory supplied within the unit, but must be field installed. LPG-10 2ff7e9595c


0 views0 comments

Recent Posts

See All

Comments


bottom of page